1.Zhejiang Jiaogong Group Co., Ltd., Hangzhou 310051 , China ;2.School of Civil Engineering and Architecture, East China Jiaotong University, Nanchang 330013 , China ;3.State key laboratory of Safety and Resilience of Civil Engineering in Mountain Area, East China Jiaotong University, Nanchang 330013 , China ; 4.Jiangxi Tianchi Highway Technology Development Co., Ltd., Nanchang 330103 , China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为研究钢板的厚度和锚固件强度对盾构隧道接头部位加固效果,采用三维数值软件Abaqus,建立了内径5.4 m、外径 6.0 m左右各1/2标准块管片接头模型,详细探讨了钢板黏胶加固地铁隧道管片接头的力学行为。研究结果表明,加固后管片接头的力学性能受到混凝土基体、钢板、锚栓三方面的影响,使用10 mm厚的钢板能使接头刚度增强40%;当钢板厚度介于 20~30 mm时,结构承受的弯矩随外部荷载的增加也逐渐增大;当钢板厚度超过20 mm后,结构损伤模式变化不大,钢板的应力主要集中在远离接缝面的支座区域。此外,锚栓数量固定的情况下,直径增加能有效提高加固后管片接头的协同受力。采用锚粘钢内衬加固后的管片接头由于受到接头部位受压区混凝土强度的限制,钢板厚度增加接头刚度增加幅度衰减,以10~20 mm钢板厚度最佳。该研究可为采用钢环内衬加固的盾构管片设计提供理论支持。

    Abstract:

    To study the reinforcement effect of steel plate thickness and anchor strength on the joint of shield tunnel, this study used Abaqus finite element software to establish left and right half standard block pipe joint models with an inner diameter of 5.4 m and an outer diameter of 6.0 m. Based on a load structure calculation model, the mechanical properties of subway tunnel segment joints reinforced with steel plates and adhesive were studied. The results show that the mechanical properties of the segment joint after reinforcement are affected by the concrete matrix, steel plate and anchor bolt. The use of 10 mm thick steel plate can increase the stiffness of the joint by 40%. When the thickness of the steel plate is in the range of 20~30 mm, the bending moment of the structure increases with the increase of the external load. When the thickness of the steel plate exceeds 20 mm, the damage mode of the structure does not change much, and the stress of the steel plate is mainly concentrated in the bearing area away from the joint surface. In addition, when the number of anchor bolts is fixed, the increase of diameter can effectively improve the cooperative force of segment joints after reinforcement. Due to the limitation of concrete strength in the compression zone, the effectiveness of further increasing the steel plate thickness diminishes, resulting in a decreasing rate of improvement in joint stiffness. The thickness of 10~20 mm steel plate is the best. This study can provide theoretical support for the design of segmental segments reinforced by steel ring lining.

    参考文献
    相似文献
    引证文献
引用本文

张仕雄,徐松,陈佳,等. 钢板套衬加固隧道管片接头力学行为及损伤发展[J]. 华东交通大学学报,2025,42(6): 58-65.