爆炸荷载下CFRP加固混凝土子结构抗连续倒塌性能评价
DOI:
作者:
作者单位:

1.华东交通大学土木建筑学院,江西南昌 330013 ;2.天津大学建筑工程学院,天津 300354

作者简介:

通讯作者:

蒋认(1987-),男,讲师,博士,研究方向为钢筋混凝土结构抗爆炸连续倒塌。E-mail:jiangren@tju.edu.cn

中图分类号:

TU375.4

基金项目:

江西省自然科学基金项目(20242BAB25307)


Assessment of Progressive Collapse Resistance Performance of CFRP Reinforced Concrete Substructures Under Explosion Loads
Author:
Affiliation:

1. School of Civil Engineering and Architecture, East China Jiaotong University, Nanchang 330013 , China ;2. School of Civil Engineering, Tianjin University, Tianjin 300354 , China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    爆炸荷载下关键构件的损伤破坏易引发建筑结构连续倒塌,造成财产损失的同时会危及人民生命安全。现常采用纤维增强复合材料(FRP)来加固钢筋混凝土(RC)结构,但缺乏FRP加固对RC结构抗爆炸倒塌性能退化定量评价的研究。考虑到爆炸试验安全性差和费用高,本文通过LS-DYNA软件利用落锤试验机配合橡胶垫块模拟爆炸荷载对混凝土子结构进行连续倒塌分析,建立了在落锤冲击速度1~10 m/s范围内预测结构表面冲击力和持时(模拟爆炸荷载)的经验公式。基于已有文献数据验证了建立的混凝土子结构数值模型的正确性,采用能量法评价了碳纤维增强复合材料(CFRP)加固对混凝土子结构抗爆炸倒塌性能的贡献。研究结果表明:与未加固混凝土子结构相比,CFRP加固对混凝土子结构剪切模型和弯曲模型抗爆炸倒塌的贡献分别为0.383和0.409。同时,爆炸荷载下CFRP加固梁能显著提高RC子结构在压拱阶段的峰值承载力,为CFRP加固工程结构抗爆设计提供了数据支撑。

    Abstract:

    The damage of key components under blast loads can easily lead to the progressive collapse of building structures, causing property losses and endangering people's lives and safety. Fiber reinforced polymer (FRP) materials are commonly used to enhance reinforced concrete (RC) structures, but there is a lack of quantitative assessment of the contribution of FRP-wrapped RC structures to blast-induced progressive collapse resistance. Considering the poor safety and high cost of explosion tests, this study employs a drop hammer test machine with rubber pads to simulate explosion loads on concrete substructures for progressive collapse analysis using the LS-DYNA software platform. An empirical formula was developed to predict surface explosion loads within the drop hammer impact velocity range from 1 to 10 m/s. The correctness of the established numerical model for the concrete substructure was verified based on existing literature data, and the contribution of CFRP-wrapped to the explosion-resistant collapse performance of the concrete substructure was quantitatively evaluated using the energy method. The research results indicate that, compared to the unreinforced concrete substructure, the contribution of CFRP-wrapped concrete structures to the shear model and bending model were 0.383 and 0.409, respectively. At the same time, CFRP reinforced beams can significantly improve the peak capacity of RC substructures in the compression arch action stage under explosive loads, which will provide data support for the blast-resistant design of CFRP-wrapped engineering structures.