平行换乘式地铁站车致振动特性研究
DOI:
作者:
作者单位:

1.华东交通大学轨道交通基础设施性能监测与保障国家重点实验室,江西 南昌 330013 ;2.广州地铁设计研究院股份有限公司,广东 广州 510010

作者简介:

通讯作者:

冯青松(1978—),男,二级教授,博士生导师,研究方向为轨道交通振动与噪声、轨道结构长期服役性能。E-mail:fqshdjtdx@aliyun.com。

中图分类号:

TB535;U231+4

基金项目:

国家自然科学基金项目(52468063)


Study on Vehicle-Induced Vibration Characteristics of Parallel Transfer Subway Stations
Author:
Affiliation:

1.State Key Laboratory of Performance Monitoring and Protecting of Rail Transit Infrastructure, East China Jiaotong University,Nanchang 330013 , China ; 2.Guangzhou Metro Design & Research Institute Co., Ltd., Guangzhou 510010 , China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为研究平行换乘式地铁站在不同线路列车相互影响下的结构振动特性,文章结合车辆轨道耦合动力学分析、有限元仿真及地铁车站现场测试,深入探讨振动在建筑内的传递特性,并分析列车组合运行对建筑物的影响,进而提出减振建议。研究结果表明:站台垂向振动主要集中在30~80 Hz频段,且在36,47,67 Hz 处出现明显峰值;由于入射波与反射波在顶层叠加, 振动在顶层放大,平均放大量为4.50 dB,振动横向传递衰减率约为0.51 dB/m;当两线路同时运行列车时,线路上方楼层的中间采样点Z振级高于同层两侧采样点,建议在线路上方设置生活、办公区域时,应避免将其布置在线路上方中间位置;为满足站内振动限值要求,建议将进站速度限制小于22 km/h;减振扣件的减振效果可达3.80 dB,钢弹簧浮置板除自身固有频率11~ 14 Hz外,在其他频段减振效果显著,尤其在80 Hz频段处减振效果可达28.00 dB。

    Abstract:

    To investigate the structural vibration characteristics of parallel transfer subway stations under the mutual influence of trains on different lines, this study integrates vehicle-track coupling dynamics analysis, finite element simulation, and field tests at subway stations. It analyzes the transmission characteristics of vibrations within buildings and the impact of combined train operations on structures, offering vibration reduction suggestions. The results indicate that platform vertical vibrations predominantly occur within the 30~80 Hz frequency range, with distinct peaks at 36, 47, 67 Hz. Due to the superposition of incident and reflected waves at the top layer, vibrations are amplified there, with an average amplification of 4.50 dB, and the lateral transmission attenuation rate is approximately 0.51 dB/m. When trains operate simultaneously on both lines, the Z vibration level at central sampling points above the lines is higher. To comply with vibration limits, the entry speed should be restricted to no more than 22 km/h. The vibration reduction fastener achieves an effect of 3.80 dB. Except for its inherent frequency range of 11~14 Hz, the steel spring floating plate exhibits significant vibration reduction in other frequency bands, notably reaching 28.00 dB at the 80 Hz band.

    参考文献
    相似文献
    引证文献
引用本文

冯青松,胡欣伟,张凌,等. 平行换乘式地铁站车致振动特性研究[J]. 华东交通大学学报,2026,43(1):30-38.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2024-10-26
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2026-03-13
  • 出版日期:
关闭