Experimental Study on Wind Stripping Resistance of Self -Tapping Screw Roof Slab
DOI:
CSTR:
Author:
Affiliation:

Clc Number:

TU391

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Three groups of self -tapping screw roof slabs were tested to investigate the influence of material strength and fixed position of roof slabs on the wind resistance of self-tapping screw roof slabs. The test results show that with the increase of the strength of the metal roof panel, the wind resistance of the self-tapping screw- type metal roof panel increases significantly, while the location of the self-tapping screw(at a quarter of the peak and trough) has little effect on the wind resistance of the roof panel system; when the self-tapping screw is at the peak, the wind resistance of the self-tapping screw is at a quarter of the trough according to the code and the formula calculation is safe.

    Reference
    Related
    Cited by
Get Citation

黄宏,陈杰,陈友泉,陈梦成.自攻螺钉式金属屋面板抗风揭试验研究[J].华东交通大学学报英文版,2019,36(5):97-101.
Huang Hong, Chen Jie, Chen Youquan, Chen Mengcheng. Experimental Study on Wind Stripping Resistance of Self -Tapping Screw Roof Slab[J]. JOURNAL OF EAST CHINA JIAOTONG UNIVERSTTY,2019,36(5):97-101