Experimental Study on the Calibration of Unencapsulated FBG Strain Sensors Under Different Mounting Methods
DOI:
CSTR:
Author:
Affiliation:

Clc Number:

U446;TP212

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Objective】As a new type of strain measuring instrument, fiber bragg gratings (FBG) strain sensors are gradually used in the field of civil engineering, and the key to their use lies in the deployment of sensors and the calibration of sensitivity coefficients according to different usage requirements and environments. The current conventional FBG installation methods are direct surface adhesion and slotting implantation.【Method】In order to determine the measurement accuracy of the two installation methods, a calibration method of the unpacked FBG sensitivity coefficient used for the pile sinking test was proposed and the calibration test of the two deployment methods was carried out by using the circular seamless steel tube as the matrix, and the calibrationresults were compared with the theoretical values.【Result】The results show that in the stage of progressive loading, the calibration coefficient obtained by slotting implantation is smaller than that by surface adhesion,while the calibration coefficient obtained by the surface adhesion is closer to the theoretical value. The calibration coefficients obtained by slotting implantation and surface adhesion were 2.84% and 0.33% respectively compared with the theoretical values; In the step-by-step unloading phase, there is a certain lag in the central wavelength of the two deployment methods, but the calibration coefficient is not much different from that inthe loading stage.【Conclusion】Therefore, it is necessary to choose a reasonable fiber grating layout scheme and calibration method according to the test environment and within the test tolerance range in the process of using FBG.

    Reference
    Related
    Cited by
Get Citation

朱怀龙,王其标,朱碧堂,邱松,刘俊杰.无封装FBG应变传感器在不同布设方式下的标定试验研究[J].华东交通大学学报英文版,2024,41(1):30-37.
Zhu Huailong, Wang Qibiao, Zhu Bitang, Qiu Song, Liu Junjie. Experimental Study on the Calibration of Unencapsulated FBG Strain Sensors Under Different Mounting Methods[J]. JOURNAL OF EAST CHINA JIAOTONG UNIVERSTTY,2024,41(1):30-37

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:February 17,2023
  • Revised:
  • Adopted:
  • Online: March 20,2024
  • Published:
Article QR Code